The Sterimed Endotracheal Tube Cuffed (SMD 701C) is a medical device intended for short-term use in airway management and mechanical ventilation. It is suitable for use in general anaesthesia, intensive care, and emergency medicine. This tube is made from a non-toxic, non-irritant medical-grade clear PVC that is free from phthalates. The material is thermo-sensitive, allowing it to soften at body temperature for increased patient comfort. The high-volume, low-pressure cuff is designed to create a secure seal within the trachea, preventing aspiration and ensuring proper ventilation.
High-Volume, Low-Pressure Cuff: Provides an excellent seal against the tracheal wall, which helps in preventing aspiration and safeguarding the patient's lungs. Thermo-sensitive Material: The tube is made from a special PVC that softens at body temperature, conforming to the patient's anatomy for enhanced comfort. Radio-Opaque Line: A clear line runs the length of the tube, allowing for easy identification of the tube's position through imaging. Smooth, Atraumatic Design: Features a polished Murphy eye, a smooth distal end, and a tapered balloon end to facilitate atraumatic intubation and extubation. Universal Connector: Equipped with a standard 15mm connector at the proximal end for compatibility with ventilation equipment.
Q: What is a cuffed endotracheal tube used for?
A: A cuffed endotracheal tube has an inflatable balloon near its tip that, when inflated inside the trachea, creates a seal. This seal is designed to maintain a clear airway for mechanical ventilation, prevent air leaks, and minimize the risk of aspiration of foreign materials into the lungs.
Q: Is the Sterimed Endotracheal Tube reusable?
A: No, this endotracheal tube is sterile and intended for single-patient use only. This is a standard practice to ensure maximum hygiene, prevent cross-contamination, and maintain patient safety.
Q: What is the significance of the 3.0mm size?
A: The 3.0mm refers to the internal diameter of the tube. This measurement is critical for healthcare professionals to select the correct size for a patient, with smaller diameters like this often used for neonatal or pediatric patients.
Q: What is the function of the 'Murphy eye' on this tube?
A: The Murphy eye is a small hole on the side at the distal end of the tube which acts as a vent. Its purpose is to provide an alternative pathway for air to flow if the main opening of the tube becomes obstructed by mucus or contact with the tracheal wall.
Q: Who should use this medical device?
A: The Sterimed Endotracheal Tube is a medical device that should only be used by trained and qualified healthcare professionals, such as anesthesiologists and critical care physicians, in a controlled clinical environment.
The Sterimed Endotracheal Tube Cuffed (SMD 701C) is a medical device intended for short-term use in airway management and mechanical ventilation. It is suitable for use in general anaesthesia, inte...
Key Benefits
Aids in providing a patent airway for patients requiring mechanical ventilation or airway support. The cuffed design creates a seal that prevents the aspiration of gastric contents into the lungs. Made from biocompatible, non-toxic, and phthalate-free PVC for patient safety. The smooth surface and atraumatic tip are designed to minimize trauma during insertion and removal. Kink-resistant construction ensures the airway remains open for continuous ventilation.
Aids in providing a patent airway for patients requiring mechanical ventilation or airway support. The cuffed design creates a seal that prevents the aspiration of gastric contents into the lungs. ...
Direction for Use/Dosage
For use by trained medical professionals only. 1. Check the integrity of the cuff and the pilot balloon before use. 2. Lubricate the tube as needed for smoother insertion. 3. Insert the tube through the patient's mouth or nose into the trachea. 4. Inflate the cuff using a syringe to create a seal. 5. Confirm correct placement through clinical assessment and, if necessary, imaging using the radio-opaque line. 6. Connect the 15mm universal connector to the ventilation circuit.
For use by trained medical professionals only. 1. Check the integrity of the cuff and the pilot balloon before use. 2. Lubricate the tube as needed for smoother insertion. 3. Insert the tube throug...
Safety Information/Precaution
This product is intended for single-patient use only; do not reuse or re-sterilize. Always consult a healthcare professional for proper sizing and insertion technique. The use of a bite block or Guedel airway is recommended to prevent the patient from biting down on and occluding the tube. Continuously monitor the patient and the tube's position throughout its use. Store in a cool, dry place away from direct sunlight.
This product is intended for single-patient use only; do not reuse or re-sterilize. Always consult a healthcare professional for proper sizing and insertion technique. The use of a bite block or Gu...
Other Information
The product is E.T.O (Ethylene Oxide) sterilized and pyrogen-free. It is supplied in a sterile, individually packed peelable pouch. The material is 100% phthalate-free. The tube features a smooth interior and exterior surface to facilitate ease in intubation, suctioning, and extubation.