The Romsons Mucus Extractor is a medical device designed for aspirating secretions from the oropharynx of newborn babies to help ensure clear respiration. It features a transparent container made from medical-grade PVC or polypropylene, which allows for immediate visual inspection of the collected aspirate. This device is also suitable for obtaining mucus specimens for microbiological examination. It is a single-use, sterile product intended for use by healthcare professionals.
Transparent Chamber: The clear container allows for direct visual examination of the aspirated fluid.
Low-Friction Catheter: It is equipped with a soft, smooth-tipped catheter to facilitate trauma-free insertion and minimize discomfort for the infant.
Specimen Collection: The device is suitable for collecting mucus samples for laboratory analysis and includes a spare plug cap to securely seal the container for transport.
Sterile and Single-Use: Each extractor is individually packed in a peelable blister pack to maintain sterility and is intended for one-time use to prevent cross-contamination.
Medical-Grade Material: The device is manufactured from non-toxic, medical-grade PVC or polypropylene, ensuring its suitability for use with newborns.
Q: What is the Romsons Mucus Extractor used for?
A: The Romsons Mucus Extractor is a medical device designed for the aspiration of secretions from the oropharynx (the part of the throat behind the mouth) in newborn babies to help ensure they can breathe freely.
Q: Is this device sterile and can it be reused?
A: The device is supplied in a sterile, individually packed peelable blister pack and is intended for single use only. Reusing the device is not recommended as it can lead to cross-contamination and compromise sterility.
Q: Can the collected mucus be used for laboratory tests?
A: Yes, the extractor is also suitable for obtaining a mucus specimen for microbiological examination. It comes with a spare plug cap to seal the container for secure transportation of the specimen to a laboratory.
Q: Who is qualified to use this mucus extractor?
A: This is a medical instrument intended for use by trained healthcare professionals, such as doctors and nurses, in a clinical setting. It should be used as directed by a healthcare professional.
Q: What is the capacity of the container and what is it made of?
A: The transparent container has a capacity of 25 ml. It is manufactured from non-toxic, medical-grade PVC or polypropylene, which allows for immediate visual examination of the collected aspirate.
The Romsons Mucus Extractor is a medical device designed for aspirating secretions from the oropharynx of newborn babies to help ensure clear respiration. It features a transparent container made f...
Key Benefits
Designed to assist newborns with free respiration by aspirating secretions from the oropharynx.
Allows for the collection of mucus specimens for microbiological examination.
The transparent container permits immediate visual assessment of the aspirate by healthcare providers.
Features a catheter with a smooth, round tip for gentle, trauma-free insertion.
Comes with a spare cap to seal the container for safe transport or disposal.
Designed to assist newborns with free respiration by aspirating secretions from the oropharynx.
Allows for the collection of mucus specimens for microbiological examination.
The transparent...
Direction for Use/Dosage
This product should be used as directed by a healthcare professional.
Open the sterile blister pack carefully, maintaining an aseptic technique.
Connect the mucus extractor catheter to a suction source.
Gently insert the catheter into the newborn's oropharynx.
Apply controlled suction to aspirate mucus.
If the specimen is for microbiological analysis, seal the container with the spare plug cap before transport.
Dispose of the device after a single use according to biomedical waste protocols.
This product should be used as directed by a healthcare professional.
Open the sterile blister pack carefully, maintaining an aseptic technique.
Connect the mucus extractor catheter to a su...
Safety Information/Precaution
For single use only; reuse may lead to cross-infection and compromise sterility.
The device should be used by or under the guidance of a qualified healthcare professional.
Avoid forceful movements during insertion to prevent injury to the mucosal lining.
Discontinue use immediately if the infant shows signs of distress or any abnormal reaction.
Follow recommended biomedical disposal protocols after use.
For single use only; reuse may lead to cross-infection and compromise sterility.
The device should be used by or under the guidance of a qualified healthcare professional.
Avoid forceful mo...
Other Information
Product Code: GS-5018.
Capacity: 25 ml.
Material: Manufactured from transparent medical-grade PVC or Polypropylene.
Packaging: Each unit is sterile and individually packed in a peelable soft blister pack.
Store in a clean, dry place away from direct sunlight.
Product Code: GS-5018.
Capacity: 25 ml.
Material: Manufactured from transparent medical-grade PVC or Polypropylene.
Packaging: Each unit is sterile and individually packed in a peelable...