The Romsons Laryngeal Mask Excell (GS-2032) is a supraglottic airway device intended for use in maintaining an open airway during anesthesia or for immediate airway management. Made from a soft, thermo-sensitive PVC material, it is designed for non-traumatic insertion and patient comfort. This anatomically engineered mask is suitable for routine and elective surgical procedures, providing an alternative to endotracheal intubation in certain clinical scenarios.
Thermo-Sensitive Material: Constructed from soft PVC that adapts to the body's temperature, contributing to patient comfort during use.
Anatomical Design: Features an anatomically correct curve and an ergonomically shaped tube to facilitate straightforward insertion and a firm grip.
Integrated Safety Features: The cuff and airway tube are molded as a single unit to enhance safety. It also includes aperture bars to help prevent the epiglottis from blocking the ventilation lumen.
Clear Markings: The ventilation tube is clearly marked with the mask size, recommended patient weight, and cuff inflation volume for procedural accuracy.
Pilot Balloon: A pilot balloon provides a tactile indication of the cuff's inflation level and is color-coded for size identification.
Q: What is the Romsons Laryngeal Mask Excell used for?
A: It is a supraglottic airway device used to keep a patient's airway open during routine and elective surgical procedures, bronchoscopic examinations, and for airway recovery.
Q: Who is the size 2.5 laryngeal mask intended for?
A: The size 2.5 mask is designed for patients weighing between 20 and 30 kg.
Q: What material is this laryngeal mask made from?
A: The mask is made from a soft, thermo-sensitive Polyvinyl Chloride (PVC) to allow for comfortable insertion for the patient.
Q: Is this a single-use device?
A: Yes, it is a disposable airway supplied as a sterile, individually packed item in a blister pack.
Q: How does the design help in its function?
A: It has an anatomically correct curve for easier insertion, a soft cuff for a good seal with low pressure, and aperture bars to help prevent the epiglottis from blocking the airway.
The Romsons Laryngeal Mask Excell (GS-2032) is a supraglottic airway device intended for use in maintaining an open airway during anesthesia or for immediate airway management. Made from a soft, th...
Key Benefits
Provides a method for maintaining an open airway during anesthesia and certain surgical procedures.
Designed for patient comfort with its soft, thermo-sensitive material that allows for an atraumatic insertion.
The anatomical shape is engineered for easy and rapid placement by a healthcare professional.
Offers an alternative to endotracheal intubation for many short surgical procedures.
Provides a method for maintaining an open airway during anesthesia and certain surgical procedures.
Designed for patient comfort with its soft, thermo-sensitive material that allows for an atra...
Direction for Use/Dosage
This device is intended for use by trained healthcare professionals only.
Before use, inspect the sterile packaging to ensure it is not damaged.
Ensure the cuff is fully deflated before insertion.
Lubricate the back of the mask with a water-soluble lubricant.
With the patient appropriately positioned, gently insert the mask and advance it until resistance is felt, indicating it is seated in the correct position over the laryngeal inlet.
Inflate the cuff with the recommended volume of air as indicated on the device.
Confirm proper placement and ventilation as per standard clinical protocols.
This device is intended for use by trained healthcare professionals only.
Before use, inspect the sterile packaging to ensure it is not damaged.
Ensure the cuff is fully deflated before ins...
Safety Information/Precaution
This product is intended for single use only; do not resterilize or reuse.
Always consult a healthcare professional before use; this is a medical device to be used by qualified personnel only.
Selecting the correct size is crucial; a mask that is too small may cause leaks, while one that is too large may be placed improperly and cause injury.
Over-inflation of the cuff can lead to complications such as sore throat or nerve injury.
Ensure a backup airway management plan is in place, as a laryngeal mask is not considered a definitive airway and can fail.
This product is intended for single use only; do not resterilize or reuse.
Always consult a healthcare professional before use; this is a medical device to be used by qualified personnel only.<...
Other Information
Store in a cool, dry place, away from direct sunlight.
The product is supplied sterile in an individual blister pack.
The size 2.5 mask is generally indicated for patients weighing between 20-30 kg.
The device contains a radiopaque line for visualization on X-rays.
Store in a cool, dry place, away from direct sunlight.
The product is supplied sterile in an individual blister pack.
The size 2.5 mask is generally indicated for patients weighing between ...