

Netmeds First Membership
Description
The Romsons Foley Trac 2 Way Foley Balloon Catheter is a flexible tube designed for urinary drainage from the bladder. It is made from latex bonded with a silicone elastomer coating for a soft feel and to reduce the risk of encrustation. This indwelling catheter features two channels: one for draining urine and the other for inflating a balloon that holds the catheter securely inside the bladder. The device is intended for short-term urethral catheterization, up to 14 days, for conditions like acute urinary retention or incontinence.
Silicone Elastomer Coated: The catheter is made of latex bonded with a silicone elastomer, providing a smooth surface for comfortable insertion and use. 2-Way Design: It features two lumens, one for urine drainage and a second with a non-return valve for inflating and deflating the retention balloon. Symmetrical Balloon: A large capacity, symmetrical balloon ensures proper anchoring in the bladder, which helps prevent leakage and bladder spasms. Atraumatic Tip: The soft, coned, closed tip with smooth, burr-free lateral eyes is designed for easy penetration and non-traumatic intubation. Color-Coded Valve: The non-return valve is color-coded for quick identification of the catheter size by healthcare professionals.
Q: What is the purpose of the Romsons Foley Trac Catheter?
A: This catheter is a flexible tube used to drain urine from the bladder when an individual cannot do so naturally due to various medical conditions. It is an indwelling catheter, meaning it can remain in the body for a period of time.
Q: What does '2-Way' signify in this catheter?
A: A 2-way catheter has two channels. One channel is for draining urine into a collection bag, and the second channel is used to inflate a balloon with sterile water, which holds the catheter in place inside the bladder.
Q: What is the function of the balloon?
A: The balloon at the tip of the catheter is inflated once inside the bladder to prevent the catheter from slipping out. It has a symmetrical, large capacity to help prevent bladder leakage.
Q: What material is the catheter made from?
A: The Romsons Foley Trac catheter is made of latex bonded with a silicone elastomer coating. This coating provides a soft feel and helps to reduce the risk of encrustation.
Q: Should this catheter be used without medical supervision?
A: No, the insertion and management of a Foley catheter should be performed by a qualified healthcare professional to ensure proper placement and to avoid complications. It is advisable to consult with a healthcare provider regarding its use.
The Romsons Foley Trac 2 Way Foley Balloon Catheter is a flexible tube designed for urinary drainage from the bladder. It is made from latex bonded with a silicone elastomer coating for a soft feel...
Key Benefits
Facilitates continuous urine drainage for individuals who are unable to urinate on their own. The silicone-coated smooth surface allows for non-traumatic intubation and removal. A symmetrical, high-capacity balloon ensures the catheter remains securely in the bladder, preventing leakage. The sterile, single-use design helps in managing hygiene during the catheterization process. Large drainage eyelets are designed for efficient and trouble-free urine flow.
Facilitates continuous urine drainage for individuals who are unable to urinate on their own. The silicone-coated smooth surface allows for non-traumatic intubation and removal. A symmetrical, high...
Direction for Use/Dosage
This product is intended for use by a qualified medical professional only. Using an aseptic technique, lubricate the tip of the catheter. Gently insert the catheter through the urethra into the bladder until urine begins to flow. Inflate the retention balloon using a syringe with sterile water through the designated valve port. The FG-18 size has a balloon capacity of 30-50 ml. Connect the drainage funnel to a sterile urine collection bag, ensuring the bag is kept below the level of the bladder.
This product is intended for use by a qualified medical professional only. Using an aseptic technique, lubricate the tip of the catheter. Gently insert the catheter through the urethra into the bla...
Safety Information/Precaution
For single use only. Do not reuse, re-sterilize, or use if the package is opened or damaged. This product should only be administered by or under the supervision of a qualified healthcare professional. This product contains natural rubber latex, which may cause allergic reactions in some individuals. Do not inflate the balloon with more than the recommended capacity. For the FG-18 size, the capacity is 30-50 ml. Store in a cool, dry place away from direct sunlight. Consult a healthcare provider if you experience symptoms like fever, chills, cloudy urine, bloody urine, or if the catheter falls out.
For single use only. Do not reuse, re-sterilize, or use if the package is opened or damaged. This product should only be administered by or under the supervision of a qualified healthcare professio...
Other Information
Product Code: GS-1026 Size: FG-18 (Red color-coded) Material: Silicone elastomer-coated latex Sterile and individually packed in a peelable soft blister pack. The device has a shelf life of 5 years from the date of manufacturing.
Product Code: GS-1026 Size: FG-18 (Red color-coded) Material: Silicone elastomer-coated latex Sterile and individually packed in a peelable soft blister pack. The device has a shelf life of 5 years...

