View Similar

Resmed Acucare Hospital Vented Full Face Mask (F1-4) (L) 1's

MRP ₹4,700.00 (Inclusive of all taxes)
Deliver to

    Netmeds First Membership

    Starting at just ₹[] for 3 months.
    View Plans

    Description

    The Resmed AcuCare F1-4 is a hospital-use vented full-face mask designed for non-invasive ventilation (NIV) for patients weighing over 30 kg. It covers both the nose and mouth, making it suitable for individuals who breathe through their mouth or have nasal obstructions. This disposable mask is intended for single-patient use for up to seven days, balancing hygiene and cost-effectiveness in a hospital setting. It is designed to work with common breathing circuits used in hospitals.


    Built-in Anti-Asphyxia Valve (AAV): The vented design includes an AAV for leak ventilation, and the clear elbow provides visual confirmation of this safety feature. Designed for Hospital Use: The mask is colour-coded for easy identification and is compatible with common breathing circuits found in hospitals worldwide. Single-Patient Disposable Design: Intended for one patient for up to seven days, which helps reduce the risk of cross-infection and lowers maintenance requirements in a clinical setting. Cushion and Headgear Technology: It combines a dual-wall cushion with form-fitting 3D headgear to provide a stable and comfortable seal, which can reduce pressure points and leaks. Convenient Sizing: A sizing template is included on the packaging to facilitate quick and appropriate mask selection for a better fit.


    Q: What is the primary use of the AcuCare F1-4 mask?

    A: The AcuCare F1-4 is a hospital vented full-face mask intended for single-patient use for up to 7 days in a hospital setting for non-invasive ventilation (NIV).


    Q: What does 'vented' mean in a full-face mask?

    A: A 'vented' mask has built-in exhalation ports that allow carbon dioxide to be safely released. This design is suitable for use with single-limb ventilator circuits or CPAP/BiPAP machines that do not have a separate exhalation valve.


    Q: How is the correct size for this mask determined?

    A: A sizing template is provided on the product packaging to help with quick and accurate mask selection for the patient.


    Q: Is this mask compatible with all ventilators?

    A: This mask is designed to be compatible with common breathing circuits found in hospitals and is specifically indicated for use with ResMed ventilators that have a 'Full face' mask setting. For other devices, it is advisable to consult the manufacturer's compatibility list.


    Q: How should the AcuCare F1-4 mask be cleaned?

    A: This is a disposable mask intended for single-patient use and should be discarded if heavily soiled. If lightly soiled, the inside may be wiped with a clean cloth and water, but it should not be disassembled for cleaning. Always follow hospital protocols and manufacturer instructions for handling.

    The Resmed AcuCare F1-4 is a hospital-use vented full-face mask designed for non-invasive ventilation (NIV) for patients weighing over 30 kg. It covers both the nose and mouth, making it suitable f...Read More

    Key Benefits

    The full-face design accommodates patients who breathe through their mouth or require higher pressures. An integrated anti-asphyxia valve (AAV) allows for the release of exhaled air in case of ventilator failure, contributing to patient safety. The disposable, single-patient-use design for up to 7 days helps in managing hygiene and reducing cross-contamination risks in a hospital environment.

    The full-face design accommodates patients who breathe through their mouth or require higher pressures. An integrated anti-asphyxia valve (AAV) allows for the release of exhaled air in case of vent... Read More

    Direction for Use/Dosage

    Use the sizing template on the package to select the correct mask size. Position the mask cushion to cover the patient's nose and mouth, then pull the headgear over their head. Hold the mask in place and pull the side straps, passing them below the ears. Adjust the top and side straps to ensure a comfortable seal without overtightening. The side straps should be slightly tighter than the top one. Connect the mask to the ventilator system and begin ventilation as per the operating instructions. If there are leaks, reposition the mask and readjust the headgear.

    Use the sizing template on the package to select the correct mask size. Position the mask cushion to cover the patient's nose and mouth, then pull the headgear over their head. Hold the mask in pla... Read More

    Safety Information/Precaution

    This mask is intended for single-patient use for a maximum of seven days to avoid cross-contamination. It should only be used for patients weighing more than 30 kg (66 lbs) who have been prescribed non-invasive positive airway pressure therapy. Consult a healthcare professional before use, especially if you have pre-existing dental conditions, as the mask may cause tooth, gum, or jaw soreness. Ensure the vent holes are kept clear to function correctly. Do not expose any part of the mask to direct sunlight, as this may cause deterioration. If any serious incidents occur while using this device, they should be reported to ResMed and the relevant competent authority.

    This mask is intended for single-patient use for a maximum of seven days to avoid cross-contamination. It should only be used for patients weighing more than 30 kg (66 lbs) who have been prescribed... Read More

    Other Information

    The mask is disposable and should be discarded if heavily soiled. For light soiling, the inside can be wiped with a clean cloth and water. Do not disassemble the mask for cleaning. For any inquiries regarding the product, please contact ResMed's customer service department.

    The mask is disposable and should be discarded if heavily soiled. For light soiling, the inside can be wiped with a clean cloth and water. Do not disassemble the mask for cleaning. For any inquirie... Read More