    The Smith & Nephew Portex Polar Preformed Tracheal Tube is a sterile, single-use device intended for airway management. It is specifically designed for oral intubation during surgical procedures involving the head, neck, or mouth. The preformed shape helps to move breathing circuit connections away from the surgical field, allowing for improved access. Made from clear PVC, it allows for visualization of moisture condensation. This tube features a Profile Soft-Seal cuff to create a secure seal within the trachea.


    Preformed Shape: The tube has a preformed south-facing bend, which directs the tube downward, improving surgical access to the facial area. Profile Soft-Seal Cuff: Features a soft, low-pressure, high-volume cuff designed to minimize the risk of trauma while providing an effective seal to prevent aspiration. Clear PVC Construction: The tube is made from clear Polyvinyl Chloride, which allows medical staff to see condensation from the patient's breath. Murphy Eye: Incorporates a smoothly formed Murphy eye at the distal end to reduce the risk of airway obstruction. Radiopaque Line: A blue radiopaque line is integrated into the tube wall to allow for confirmation of correct placement via X-ray.


    Q: Is this tracheal tube for single-use?

    A: Yes, this tracheal tube is a sterile, single-use medical device designed to be used for one patient and then disposed of to prevent cross-contamination.


    Q: What does 'preformed' mean in the context of this tube?

    A: The term 'preformed' indicates that the tube is shaped with a specific bend. This south-facing polar design helps to keep the breathing circuit away from the surgical field, which is particularly useful in head and neck surgeries.


    Q: Who is qualified to use this product?

    A: This is a specialized medical device intended for use only by qualified healthcare professionals, such as anesthesiologists, in a controlled clinical environment like a hospital or surgical center.


    Q: What is the purpose of the cuff on this tube?

    A: The high-volume, low-pressure cuff is designed to create a seal against the tracheal wall. This helps in delivering positive pressure ventilation and minimizes the risk of aspiration.


    Q: What material is the tube made from?

    A: The tube is manufactured from clear Polyvinyl Chloride (PVC), which allows for the observation of moisture condensation from the patient's breath.

    The Smith & Nephew Portex Polar Preformed Tracheal Tube is a sterile, single-use device intended for airway management. It is specifically designed for oral intubation during surgical procedures in...Read More

    Key Benefits

    Facilitates airway management during complex head, neck, and facial surgeries. The preformed design helps keep breathing circuit connections away from the operative area. The soft cuff is designed to create a seal at low pressures, reducing potential trauma to the trachea. Aids in preventing aspiration by providing a secure seal within the airway. The clear material and radiopaque line assist clinicians in the correct placement and monitoring of the tube.

    Facilitates airway management during complex head, neck, and facial surgeries. The preformed design helps keep breathing circuit connections away from the operative area. The soft cuff is designed ... Read More

    Direction for Use/Dosage

    This product is intended for use by trained medical professionals only. It is used for oral endotracheal intubation to establish and maintain a patent airway. The depth of insertion should be determined by clinical judgment, though depth markers are provided for guidance. After intubation, the tube should be securely fastened to prevent movement. The patency of the lumen must be maintained through regular suctioning as needed.

    This product is intended for use by trained medical professionals only. It is used for oral endotracheal intubation to establish and maintain a patent airway. The depth of insertion should be deter... Read More

    Safety Information/Precaution

    For single use only. Do not reuse, reprocess, or re-sterilize. This device should only be used by healthcare professionals trained in airway management. Always check the integrity of the cuff and the breathing system connectors before and after establishing the circuit. Patients should be adequately humidified to minimize the risk of encrustation within the tube. Consult a healthcare professional before use, as the selection of the correct size and type of tube is dependent on the patient's specific clinical needs.

    For single use only. Do not reuse, reprocess, or re-sterilize. This device should only be used by healthcare professionals trained in airway management. Always check the integrity of the cuff and t... Read More