    Johnson & Johnson Ethicon Vicryl Plus (VP2350) is a sterile, synthetic absorbable surgical suture intended for use in general soft tissue approximation and/or ligation. This braided suture is composed of Polyglactin 910 and is coated with triclosan, an antibacterial agent, to help reduce the risk of infection at the surgical site. Its design ensures it can be smoothly integrated into the body's natural healing processes, providing support for 14 to 28 days while tissues heal.


    Antibacterial Coating: Coated with IRGACARE MP (Triclosan), which helps to inhibit the colonization of bacteria on the suture. Absorbable Material: Made from Polyglactin 910, a copolymer of 90% glycolide and 10% lactide, which is absorbed by the body through hydrolysis, eliminating the need for suture removal. Braided Construction: The multifilament, braided design offers good handling characteristics and knot security. Predictable Strength Retention: Provides a predictable breaking strength retention profile to support tissue during the critical healing period of 14 to 28 days. Violet Color for Visibility: The suture is dyed violet to enhance visibility against tissues during surgical procedures.


    Q: What is a Vicryl Plus suture?

    A: It is a sterile, synthetic, absorbable surgical suture made of Polyglactin 910, intended for use in general soft tissue approximation and/or ligation. It is designed to be absorbed by the body, eliminating the need for suture removal.


    Q: What is the 'Plus' feature in this suture?

    A: The 'Plus' indicates that the suture is coated with triclosan, an antibacterial agent, which helps to inhibit the colonization of bacteria on the suture and reduce the risk of infection at the surgical site.


    Q: How long does this suture provide wound support?

    A: It provides support for 14 to 28 days while tissues heal, with a predictable breaking strength retention profile during this critical period.


    Q: What types of procedures is this suture used for?

    A: This suture is indicated for general soft tissue approximation and/or ligation, but it is not for use in ophthalmic, cardiovascular, or neurological tissues.


    Q: Is this product for general consumer use?

    A: No, this product is intended for use by qualified healthcare professionals only. The selection and implantation of the suture should be based on the patient's condition and the surgical procedure.

    Johnson & Johnson Ethicon Vicryl Plus (VP2350) is a sterile, synthetic absorbable surgical suture intended for use in general soft tissue approximation and/or ligation. This braided suture is compo...Read More

    Key Benefits

    Aids in preventing bacterial colonization on the suture, which is associated with surgical site infections. Gradually absorbs into the body, which means there is no need for a second procedure for suture removal. Provides reliable, short-term wound support during the initial phases of healing. The braided design allows for secure knot tying and placement. Its proprietary coating is designed to minimize the drag force when passing through tissue.

    Aids in preventing bacterial colonization on the suture, which is associated with surgical site infections. Gradually absorbs into the body, which means there is no need for a second procedure for ... Read More

    Direction for Use/Dosage

    This product is intended for use by qualified healthcare professionals only. The selection and implantation of the suture should be based on the patient's condition, surgical procedure, surgical experience, and wound size. Before use, inspect the packaging to ensure it is not damaged or compromised. Handle the suture with sterile instruments. Employ the appropriate wound closure technique as per surgical requirements. This suture is indicated for general soft tissue approximation and/or ligation, but not for use in ophthalmic, cardiovascular, or neurological tissues.

    This product is intended for use by qualified healthcare professionals only. The selection and implantation of the suture should be based on the patient's condition, surgical procedure, surgical ex... Read More

    Safety Information/Precaution

    This product is for single-use only. Do not re-sterilize or reuse. Do not use if the package is opened or damaged. The use of this suture may be inappropriate in patients with known sensitivities or allergies to its components, including Polyglactin 910 and triclosan. It is not intended for use where extended approximation of tissue under stress is required. Always consult a healthcare professional for proper use and to discuss any potential adverse reactions or contraindications based on the patient's medical condition.

    This product is for single-use only. Do not re-sterilize or reuse. Do not use if the package is opened or damaged. The use of this suture may be inappropriate in patients with known sensitivities o... Read More

    Other Information

    Manufactured by: Johnson & Johnson Ltd., Aurangabad, India. Country of Origin: India. Sterilization: Sterilized by Ethylene Oxide (ETO). Storage: Store in a cool, dry place, away from direct heat and moisture. Ensure the sterile package is not compromised before use.