Inspired Sterile Heat and Moisture Exchange Filter (521-013) (Straight) 1's

MRP ₹535.00 (Inclusive of all taxes)
Deliver to

    Netmeds First Membership

    Starting at just ₹[] for 3 months.
    View Plans

    Description

    This Inspired Sterile Heat and Moisture Exchange Filter is a single-use respiratory care device designed for use in mechanically ventilated patients. It functions by capturing heat and moisture from the patient's exhaled breath and returning it to the air they inhale. This process helps to keep the airways moist, preventing dryness and irritation. Additionally, the integrated filter provides a barrier against airborne particles, including bacteria and viruses, which aids in preventing cross-contamination between the patient and the ventilator equipment.


    Dual-Action Functionality: This device combines the benefits of a heat and moisture exchanger (HME) with a breathing filter, simultaneously humidifying the air and protecting against contaminants. High-Efficiency Filtration: It incorporates an electrostatic filter medium that is proficient in filtering bacteria and viruses, reducing the risk of cross-infection for the patient. Passive Humidification: By retaining the patient's exhaled warmth and moisture, it helps prevent the drying of mucous membranes and the thickening of secretions without needing an external power or water source. Sterile and Single-Use: Each filter is supplied in a sterile condition and is intended for single-patient use to maintain aseptic conditions and prevent patient-to-patient contamination. Standardized Connectors: Equipped with universal connectors (22M/15F), it ensures compatibility with standard breathing circuits, tracheostomy tubes, and endotracheal tubes.


    Q: What is the primary function of the Inspired Sterile Heat and Moisture Exchange Filter?

    A: This device, also known as an HME filter, is designed to capture heat and moisture from a patient's exhaled air and return it during the next inhalation, which helps to keep the airway moist.


    Q: What are the filtration efficiencies of this HME filter?

    A: The Inspired HMEF 521-013 has a bacterial filtration efficiency of over 99.9999% and a viral filtration efficiency of over 99.99%.


    Q: Who is this HME filter intended for?

    A: This filter is designed for adult patients with a tracheostomy or those on mechanical ventilation to assist with breathing and provide humidification.


    Q: How often should the HME filter be replaced?

    A: It is recommended to replace the HME filter at least every 24 hours, or more frequently if it becomes clogged with secretions.


    Q: What are the connection specifications for this filter?

    A: The filter features universal 22F/15M - 22M/15F connectors, ensuring compatibility with standard breathing circuits.

    This Inspired Sterile Heat and Moisture Exchange Filter is a single-use respiratory care device designed for use in mechanically ventilated patients. It functions by capturing heat and moisture fro...Read More

    Key Benefits

    The Inspired Sterile Heat and Moisture Exchange Filter offers several advantages for respiratory care:
    Maintains airway health by providing passive humidification, which helps prevent airway dryness, irritation, and the formation of mucus plugs.
    Aids in infection control by filtering bacteria and viruses from the breathing circuit, protecting both the patient and the respiratory equipment from contamination.
    Simulates the natural warming and moisturizing function of the upper airways, which is bypassed during mechanical ventilation or for patients with a tracheostomy.

    The Inspired Sterile Heat and Moisture Exchange Filter offers several advantages for respiratory care:
    Maintains airway health by providing passive humidification, which helps prevent airway dr... Read More

    Direction for Use/Dosage

    This device should only be used under the guidance of a qualified healthcare professional. Aseptically remove the filter from its sterile packaging. Connect the filter between the patient's airway connection (e.g., endotracheal tube or tracheostomy tube) and the ventilator breathing circuit. Replace the filter as per hospital protocol or clinical guidelines, typically every 24 hours, or sooner if it becomes visibly soiled or if breathing resistance increases.

    This device should only be used under the guidance of a qualified healthcare professional. Aseptically remove the filter from its sterile packaging. Connect the filter between the patient's airway ... Read More

    Safety Information/Precaution

    For single-patient use only. Do not reuse or re-sterilize. Do not use the filter if the packaging is open or damaged. It is advisable to consult with a healthcare provider before using this product, especially to understand the appropriate replacement schedule. The device should be monitored regularly for secretions and replaced if it becomes occluded.

    For single-patient use only. Do not reuse or re-sterilize. Do not use the filter if the packaging is open or damaged. It is advisable to consult with a healthcare provider before using this product... Read More

    Other Information

    This product is intended for use in clinical settings such as intensive care units (ICUs) and operating rooms. Store in a clean, dry place away from direct sunlight.

    This product is intended for use in clinical settings such as intensive care units (ICUs) and operating rooms. Store in a clean, dry place away from direct sunlight.