    The Becton Dickinson BD Venflon I.V. Cannula is a peripheral intravenous catheter designed for administering fluids or medications directly into the bloodstream. The 16G size is suited for situations requiring high flow rates, such as rapid fluid replacement or blood transfusions. Its design incorporates features for both patient comfort and clinician safety. The catheter material is designed to reduce vein trauma, and an integrated port allows for medication administration without needing another needle stick.


    Integrated Injection Port: Allows for the administration of medications during infusion without the use of an additional needle. Back-Cut Needle Bevel: The design of the needle and the tapered end of the catheter are intended to allow for easier insertion and minimize the risk of vein damage. Flexible Wings: These help to stabilize the cannula once it is in the vein and provide a point for securement. Biocompatible Catheter Material: The cannula is made from PTFE, a material that helps reduce trauma to the vein. Ergonomic Design: The grip is constructed to accommodate various insertion techniques by healthcare professionals.


    Q: What is the primary use of a 16G cannula?

    A: A 16G IV cannula is typically used for administering intravenous fluids, medications, or blood products, and for regular blood sampling. Its larger size is suitable for rapid infusions required in settings like major surgery or trauma care.


    Q: What material is the BD Venflon cannula made from?

    A: This cannula is made from BD Vialon™ biomaterial, which is designed to soften inside the vein, potentially reducing the risk of complications like phlebitis.


    Q: Does this cannula have an injection port?

    A: Yes, the BD Venflon features an integrated injection port with a snap cap, allowing for the administration of medication without needing a separate needle stick.


    Q: Is this product intended for self-use?

    A: No, this is a medical device intended for single use by qualified healthcare professionals in a clinical setting. Proper training is necessary for its insertion and management.


    Q: Are there features to enhance insertion success?

    A: Some versions of the BD Venflon Pro may include BD Instaflash™ Needle Technology, which has a notched needle designed to provide visual confirmation of vessel entry to improve first-attempt success.

    The Becton Dickinson BD Venflon I.V. Cannula is a peripheral intravenous catheter designed for administering fluids or medications directly into the bloodstream. The 16G size is suited for situatio...Read More

    Key Benefits

    Designed for procedures requiring rapid fluid administration, such as in emergency care or during surgery. The injection port offers a way to administer intermittent medications, which can enhance patient comfort by avoiding repeated needle sticks. The construction of the catheter aims to reduce the chance of vein damage during insertion.

    Designed for procedures requiring rapid fluid administration, such as in emergency care or during surgery. The injection port offers a way to administer intermittent medications, which can enhance ... Read More

    Direction for Use/Dosage

    This product is intended for use by qualified healthcare professionals only. The general procedure involves: 1. Follow aseptic technique throughout the procedure. 2. Prepare the insertion site as per institutional protocol. 3. Perform the venipuncture at a low angle, observing for blood return in the flashback chamber. 4. Once blood is observed, lower the cannula almost parallel to the skin and advance the entire system slightly to ensure the catheter tip is inside the vein. 5. Hold the needle stationary and advance the catheter into the vein. 6. Withdraw the needle while securing the catheter, and dispose of the needle in an appropriate sharps container. 7. Secure the cannula wings to the skin. 8. Connect the IV tubing and commence infusion as prescribed.

    This product is intended for use by qualified healthcare professionals only. The general procedure involves: 1. Follow aseptic technique throughout the procedure. 2. Prepare the insertion site as p... Read More

    Safety Information/Precaution

    For use by trained medical personnel only. This is a single-use, sterile device; do not reuse or re-sterilize. Do not use if the packaging is opened or damaged. Always read the label and follow the directions for use. Consult a healthcare professional before use, especially for patients with known sensitivities or medical conditions. There is a potential risk of blood or fluid loss from the injection port, which could be pronounced with larger cannulae or when used with rapid infusers.

    For use by trained medical personnel only. This is a single-use, sterile device; do not reuse or re-sterilize. Do not use if the packaging is opened or damaged. Always read the label and follow the... Read More

    Other Information

    Country of Origin: India. Manufacturer Address: Becton Dickinson India Pvt Ltd, Plot- 1 Investate Bawal, Haryana - 123 501. The product is free of DEHP, Latex, and PVC. Store in a cool, dry place away from direct sunlight.