Dolphin Petcryl Polyglactin 910 is a synthetic, absorbable surgical suture with a braided and coated structure, intended for general soft tissue approximation and ligation. Composed of 90% glycolide and 10% L-lactide, it is designed for predictable absorption through hydrolysis. The coating facilitates a smooth passage through tissue, and the braided design offers dependable handling and knot placement. This suture provides an alternative to catgut sutures, offering more predictable absorption and minimal tissue reaction.
Synthetic Absorbable Material: Composed of a copolymer of 90% glycolide and 10% L-lactide which is absorbed by the body through hydrolysis.
Braided and Coated Design: The braided construction allows for easy handling and secure knot tying, while the coating ensures smooth passage through tissues with minimal friction.
Predictable Absorption Profile: It retains approximately 70% of its initial tensile strength at 14 days post-implantation, with complete absorption between 56 and 70 days.
Minimal Tissue Reaction: Being synthetic, it causes only a mild inflammatory response during the absorption process, making it suitable for a variety of procedures.
Versatile Application: Indicated for use in general soft tissue approximation and ligation, including ophthalmic, gynecological, and gastrointestinal surgeries.
Q: What is Dolphin Petcryl Polyglactin 910 suture?
A: Petcryl Polyglactin 910 is a synthetic, absorbable surgical suture made from a copolymer of 90% glycolide and 10% L-lactide. It is braided and coated to allow for smoother passage through tissues.
Q: Is this suture absorbable by the body?
A: Yes, it is an absorbable suture. The body absorbs it through a process called hydrolysis, and absorption is typically complete between 56 and 70 days.
Q: What are the common surgical applications for this suture?
A: This suture is indicated for general soft tissue approximation and ligation. It is frequently used in general surgery, obstetrics/gynecology, and gastro-intestinal tract surgery. However, it is not intended for use in cardiovascular or neurological tissues.
Q: How much of its original strength does the suture retain over time?
A: The suture retains approximately 70-75% of its initial tensile strength at 14 days post-implantation. Some studies show strength retention of about 50% after three weeks.
Q: What is the purpose of the coating on the suture?
A: The suture is coated with a mix of poly (glycolide-co-L-lactide) and calcium stearate. This coating provides a smoother surface, which reduces drag and minimizes trauma as it passes through tissue, and also facilitates easier handling and knot tying.
Dolphin Petcryl Polyglactin 910 is a synthetic, absorbable surgical suture with a braided and coated structure, intended for general soft tissue approximation and ligation. Composed of 90% glycolid...
Key Benefits
Provides reliable wound support during the critical healing period, retaining substantial tensile strength after implantation.
The synthetic composition minimizes tissue reactivity and reduces the risk of inflammatory responses compared to natural sutures.
Eliminates the need for a second procedure for suture removal due to its absorbable nature, which can be more comfortable for the patient.
Offers good handling and knot security for surgeons, contributing to dependable wound closure.
The predictable absorption rate allows for a standard post-operative care plan.
Provides reliable wound support during the critical healing period, retaining substantial tensile strength after implantation.
The synthetic composition minimizes tissue reactivity and reduces ...
Direction for Use/Dosage
To be used by qualified healthcare professionals who are familiar with surgical procedures and techniques involving absorbable sutures. The selection and implantation of the suture should be based on the patient's condition, surgical experience, the type of tissue, and the size of the wound.
To be used by qualified healthcare professionals who are familiar with surgical procedures and techniques involving absorbable sutures. The selection and implantation of the suture should be based ...
Safety Information/Precaution
This product is for single use only. Do not reuse or re-sterilize, as this may compromise the integrity of the suture.
Do not use if the package is opened or damaged.
Discard any opened, unused sutures.
Users should be familiar with surgical procedures involving absorbable sutures before use.
Consult a healthcare professional for any questions or concerns regarding the use of this product.
Not for use in cardiovascular or neurological tissues where extended tissue approximation is required.
This product is for single use only. Do not reuse or re-sterilize, as this may compromise the integrity of the suture.
Do not use if the package is opened or damaged.
Discard any opened, un...
Other Information
Store the sutures in a cool, dry place, away from direct heat and moisture, at a temperature between 15°C and 30°C.